Milestone Instruments
Milestone Instruments
Milestone Instruments
Milestone Instruments Milestone Instruments
Milestone Instruments
Home
Homepage
Milestone Instruments Milestone Instruments Milestone Instruments Milestone Instruments Milestone Instruments
Home » Our Products » Cement, Lime, Plaster & Mortar

Cement, Lime, Plaster & Mortar

1 - 2
Crushing And Grinding MI.CE-1018 Pulveriser
Milestone Instruments
Pulveriser
Pulveriser machines are used to smash materials into tiny shards or granules. Pulveriser machines can crush all types of items, including plastic, glass, aluminium, concrete, coal, rock, resin, tires, and medical waste. Pulverizer machines come in a number of different forms. Hammer mills, ring mills, double roll crushers, granulators, impactors, and shredders are all forms of pulverizer machines. Pulverizer is used in plastic industry for Plastics Pulverizing Including PVC Recycling, Rotational Molding, Compounding and Master batching










MI.CE-1019 Jaw Crusher
Milestone Instruments
Jaw crusher
A crusher is a machine designed to reduce large rocks into smaller rocks, gravel, or rock dust. Crushers may be used to reduce the size, or change the form, of waste materials so they can be more easily disposed of or recycled, or to reduce the size of a solid mix of raw materials (as in rock ore), so that pieces of different composition can be differentiated. Crushing is the process of transferring a force amplified by mechanical advantage through a material made of molecules that bond together more strongly.
The following size of jaw crusher is available.
Jaw Size Motor Capacity Input Output
4" x 6" 3 HP 25-30 mm 6-20 mm
6" x 8" 5 HP 45-50 mm 10-22 mm
8" x 12" 10 HP 65-70 mm 12-25 mm
12" x 16" 10 HP 90-100 mm 20-30 mm
15" x 24" 15 HP 100-150 mm 25-55 mm




Laboratory Ball Mill,
Milestone Instruments
Lab Ball Mill
Laboratory Ball Mill is primarily designed for grinding pigments. The material is ground at a specific speed by using a specific quantity of grinding media (steel balls) for a specific period. The equipment is used for making the ground cement samples in the laboratory. Apart from the cement industry, it is also used in the paint, plastic, granite and tile industries.










MI.CE-1020
Laboratory Ball Mill, 5 Kg capacity without steel balls
MI.CE-1021
Laboratory Ball Mill, 10 Kg capacity without steel balls
Other size is also available
The following size of ball is available at extra cost.




MI.CE-1022 Vibrating Machine
Milestone Instruments
Vibrating Machine
A specially designed Vibration Machine is used for vibrating the mix in moulds according to strictly controlled programmer at a frequency of 12,000 ± 400 cycles per minute. The Vibrator is mounted over coiled springs and the vibrations are developed by means of a revolving eccentric shaft. The center of gravity of the vibrator, including the cube and mould, is either at the center of the eccentric shaft or within 25 mm below it. The simple design of the machine facilitates easy assembly and dismantling of the cube moulds. The machine is suitable for operation on 230 V, 50 Hz, and single-phase, AC supply. Each machine is supplied with one cube mould.
Meets:- IS: 4031
The following mould can be ordered as extra
Mould, M. Steel, for 70.6 cm cube
Note:- The machine can certified for its frequency by the National Council of Cement and Building Materials (NCCBM) at Extra Cost. Consistency And Setting-Time




Vicat Method
Milestone Instruments
Vicat Apparatus
Apparatus described below have been designed for determining the normal consistency, standard consistency and time of setting of cement and lime in accordance with IS, ASTM, BS and AASHO specifications. The procedure, as recommended in various standards, is for determining the quantity of water required to produce a cement paste of standard consistency. The standard consistency is attained when the 10 mm plunger of the apparatus penetrates the material to a pre-determined depth under free-fall. A new sample is prepared and tested with initial and final needles in accordance with the procedure described in various specifications. Vicat Apparatus consists of a frame bearing a movable rod with a cap at top and a Vicat mould in the form of the frustum of a cone, (80+5)/70 + 5mm dia at the base,(70mm+5mm) /60 mm at the top and 40 mm high, and with a glass base plate of minimum 2.5 mm thickness with various models of Vicat apparatus as per standard specifications.
Meets:- IS: 2645, IS:2542 (Part-2), IS: 1727,IS:5513, BS: 12, 146, 915, 1370, 4027, 4246, 4248, ASTM C-91, C-141, C-187,C-308, C-359, C-472 & AASHO T-129, E-131
Two models of Vicat Apparatus are offered
MI.CE-1023 Vicat Apparatus
The apparatus includes one each of: Vicat Mould, Glass Base Plate, Initial Needle (in Plastic Case), Final Needle (in Plastic Case)Consistency Plunger (in Plastic Case) Meets:- IS: 5513
MI.CE-1024 Vicat Apparatus with Dashpot
This apparatus includes Dashpot to facilitate the gentle lowering of the moveable rod
Meets:- IS: 5513
MI.CE-1024001
Vicat Mould Split Type, with Clamping Ring




Shrinkage Bar Mould
ALength Comparator listed in the concrete section determines the change in length of the specimen. Two models are offered. One is provided with stainless steel smooth reference points and the other is provided with knurled and threaded reference points. Both the models are available as single mould and multiple mould compartments. Each mould is supplied complete with base plate and two reference points per compartment of mould. Mould size: 25 x 25 mm section and 250 mm effective length (Distance between two inner-most of the reference points)
Meets:- IS: 10086, IS: 4031, ASTM C-151
The models are available in three kinds of apartments i.e. : One, Two, Four with smooth and knurled threaded reference points.
MI.CE-1025 Shrinkage bar Mould, Single








MI.CE-1026 Shrinkage Bar Mould, Double





MI.CE-1027 Shrinkage Bar Mould, Four
Optional Extra
Set of 20, Smooth Reference Points
Set of 20, knurled and threaded reference point




Flow And Workability Of Mortar And Lime
The Flow Test is carried out on cement mortars, pozzolanas and limes. The specimen is placed on a flow table top which is then raised and dropped through a known height.
Meets:- IS: 1727, IS: 2645, IS: 4031, IS: 6932 (Part 8)
MI.CE-1029 Flow Table, Manually Operated
The Flow table consists of a brass tabletop 250+ 2.5 mm dia, mounted on a rigid stand. The table top is reinforced with equally disposed ribs and allowed to drop through 12 mm by a ground and hardened Manual cam.
IS: 5512, IS:2250




MI.SO-1011 Cone Penetrometer Method
Milestone Instruments
Automatic Cone Penetrometer
Meets:- IS: 2720 (Part 5) - 1985, IS: 11196 - 1985,

Available in two options as follows










1 - 2