MI.CE-1001 Flexural Strength, 4 KN Flexure
strength Testing Machine Electrically Operated
For the Transverse test of pozzolana and cement
mortar prisms by single point loading of a 60 mm long prism supported at 100
mm centres. Smaller loads, less than 10 N, can be applied and measured with
an accuracy of 1% in the upper four-fifths of the range. The load is
increased at the rate of 40- 60 N/sec.
Meets:- IS: 1727, IS: 4031
Gauging Trowel
IS: 4031, IS: 5515
MI.CE-1002 Gauging Trowel,
200 mm long blade, Weight 210 ± 10 g
Meets:- IS: 5515,
MI.CE-1003 Gauging Trowel
150 mm long blade with straight edge
Meets:- IS: 4031,
MI.CE-1004 Gillmore Needle Apparatus
For determining setting time of hydraulic cement.
The apparatus consist of a base plate with a vertical shaft and two
horizontal arms, the lower arm being adjustable for height and supplied
complete with one initial needle, one final needle and a base plate.
ASTM C 91, C414
Replacement Parts
Initial Needle 1/12-inch dia. ¼ lb. wt.
Final Needle 1/24-inch dia. 1lb.wt.
Glass Base Plate
Strength Of Cement And Mortar
Compressive Strength
The failure loads of mortar cubes can vary
considerably according to the type of cement and the period of curing.
However, a capacity between 50 kN and 500 kN encompasses the majority of
test conditions. A 500 KN Compression Testing Machine is suitable for
testing mortar cubes, cement mortar and pozzolana cubes of 50 mm.
For More Details See Concrete
Testing Instruments
MI.CE-1005 Jolting Apparatus
The jolting apparatus consists of a rectangular
table, rigidly connected by two support arms to spindle at a horizontal
distance of 800 mm from the center of the table. The table can be raised and
allowed to fall freely by a cam, which is connected to a motor. The cam
rotates at a rate of 60 rpm. A stroke counter, fitted with micro switch, is
provided, which stops the machine after 60 jolts. Locating pins are provided
for mounting the mould compartments on the table. The mould, surrounded by
the hopper, can be clamped rigidly to the table.
Supplied complete with mould and hopper. And operation with 230 V, 50
cycles, single phase, AC Supply.
Meets:- IS: 10078
MI.CE-1005001
Mould for Flexural Prism, M. Steel, three
compartments, each of 40.1 x 40 x 160mm
MI.CE-1005002
Demoulding Apparatus
Laboratory Cement Autoclave
It consists of a stainless steel cylinder with an
insulated cover, mounted on a sturdy supporting frame, enclosed in a heat
insulated metal housing, attractively finished. The attached control unit
encloses a sensitive pressure regulator and pressure gauge, power switches
and pilot lamps for controlling the electric heating units. Inside Chamber
dimensions: 15 cm dia x 60 cm height, with stainless steel Cylinder (20
kg/cm2 pressure capacity) Suitable for operation on 220 V, 50 Hz, Single
Phase, AC Supply and supplied complete with Test Bar Holder, Special Rack to
hold specimens above water level in the autoclave and in a vertical position
to expose them in the same manner.
Meets:- IS: 4031
MI.CE-1006 Laboratory Cement Autoclave
With analogue readout for temperature
MI.CE-1006D Laboratory Cement Autoclave, Digital
With Electronic Digital Readout for temperature
MI.CE-1006001
Autoclave mould :
Size: 25 x 25 x 282mm
MI.CE-1007 Le-Chatelier Apparatus
The soundness of ordinary and rapid hardening
portland cement, low heat portland cement and class-A limes can be
determined by an expansion test using Le-Chatelier moulds.
Meets:- IS: 5514, IS: 1727, IS: 2645, IS: 4031, IS: 6932 (Part-9), BS:
890, BS: 915, BS: 1370, BS: 4027, BS: 4226
MI.CE-1008 Le-Chatelier Flask
Meets:- IS: 4031, ASTM C-188
For determining density of powdered materials-limes, slag and hydraulic
cement. Capacity: 250ml. Neck is graduated from 0 to 1ml and from 18 to
24ml.
MI.CE-1010 Chapman Flask
Flask has two bulbs for determining approximate
percentage of voids and surface moisture in fine aggregates. Graduated to
200ml between bulbs and from 375ml up to 450ml (in 1ml divisions) above
second bulb. Meets
ASTM C70; AASHTO T142
MI.CE-1011 Le-Chatelier Mould
It consists of a small split cylinder forming a
mould 30 mm internal dia. and 30 mm high. On either side of the split
cylinder, two parallel indicating arms with pointed ends are attached. The
mould is supplied complete with two glass plates and lead weight.
Meets:- IS: 5514
MI.CE-1012 Le Chatelier Water Bath for curing 12
moulds
Note: - Le Chatelier Water Bath is also
available with Digital indicator & Controller
Mortar Mixer
This apparatus has specially been designed to
prepare cement mortar for strength determination as specified in IS: 4031.
It can also be used in mixing lime with pozzolonic materials for
determination of lime reactivity (as per IS: 1727) and for uniform mixing of
soils with additives such as lime, cement, etc. The stainless steel mixing
bowl has a capacity of 4.75 litres. The paddle, also made of stainless
steel, can have both planetary and revolving motion for uniform mixing. It
can be electrically driven at two speeds:
Meets:- IS: 10890-1984
|
|
|
Revolution of
Paddle (rpm) |
Planetary Movement
of Paddle (rpm) |
MI.CE-1013 , Mortar
Mixer |
Low Speed |
140 ± 5 |
62 ± 5 |
MI.CE-1014 , Mortar
Mixer |
High Speed |
280 ± 10 |
125 ± 10 |
MI.CE-1015 , Mortar
Mixer |
Low Speed
High Speed |
140 ± 5
280 ± 10 |
62 ± 5
125 ± 10 |
Note :- The mixer is also
available with the heating facility |
|
|
Cement Tensile Testing
The double lever tensile testing machine for cement
briquette is available in different ranges. Loading is applied automatically
by lead shots flow in manually operated units and by a travelling weight on
the lever in electrically operated model. The loading is controlled at the
rate of 226.7kg/minute and measured to 0.05kg. The machines are fitted with
precision gunmetal jaws and are provided with levelling feet. It is
available in two capacities
MI.CE-1016 Cement Tensile Testing 900 Kg
ASTM C-109
The instrument employs a friction free, accurate, double lever system, the
load being applied by means of sliding weight on the top lever. The capacity
of the units is 900 kgs.
MI.CE-1017 Cement Tensile Testing 500 Kg
Same as above but manually operated and having 500
kg capacity
Meets:- IS: 269