MI.PP-1027 Apparatus for float viscometer
This apparatus is used for determination float test
for bituminous. The apparatus consists of a float, coller, Thermometer
(Range -2 to 80 degree centigrade) and water bath.
Meets:- IS: 1210
MI.PP-1028 Viscometer Tubes for Viscosity Test
Viscometer U tube , BS/U
|
Size |
Nominal Constant
|
Viscosity Range |
B |
0.01 |
2.0-10 |
C |
0.03 |
6.0-30 |
D |
0.1 |
20-100 |
E |
0.3 |
60-300 |
F |
1 |
200-1000 |
G |
3 |
600-3000 |
H |
10 |
2000-10000 |
|
|
Viscometer Suspended level BS/IP/SL
|
Size |
Nominal Constant
|
Viscosity Range |
1 |
0.01 |
3.5-10 |
1A |
0.03 |
6.0-30 |
2 |
0.1 |
20-100 |
2A |
0.3 |
60-300 |
3 |
1 |
200-1000 |
3A |
3 |
500-3000 |
4 |
10 |
2000-10000 |
4A |
30 |
6000-30000 |
5 |
100 |
20000-100000 |
|
|
Viscometer Suspended level Shortened From
BS/IP/SL(S)
|
Size |
Nominal Constant
|
Viscosity Range |
3 |
0.01 |
3.8-10 |
4 |
0.03 |
6.0-30 |
5 |
0.1 |
20-100 |
6 |
0.3 |
60-300 |
7 |
1 |
200-1000 |
8 |
3 |
600-3000 |
9 |
10 |
2000-10000 |
|
|
Viscometer Cannanfenske for transparent liquid
BS/IP/CF
|
Size |
Nominal Constant
|
Viscosity Range |
100 |
0.015 |
3.0-15 |
150 |
0.035 |
7.0-35 |
200 |
0.1 |
20-100 |
300 |
0.25 |
50-250 |
350 |
0.5 |
100-500 |
400 |
1.2 |
240-1200 |
450 |
2.5 |
500-2500 |
500 |
8 |
1600-8000 |
600 |
20 |
4000-20000 |
|
|
Viscometer Cannanfenske for Opaque liquid ASTM-D
445
|
Size |
Nominal Constant
|
Viscosity Range |
100 |
0.015 |
3.0-15 |
150 |
0.035 |
7.0-35 |
200 |
0.1 |
20-80 |
300 |
0.25 |
50-200 |
350 |
0.5 |
100-400 |
400 |
1.2 |
240-960 |
450 |
2.5 |
500-2000 |
500 |
8 |
1600-6400 |
600 |
20 |
4000-16000 |
|
|
Viscometer U-tube Reverse flow BS/IP/RF
|
Size |
Nominal Constant
|
Viscosity Range |
2 |
0.01 |
2.0-10 |
3 |
0.03 |
6.0-30 |
4 |
0.1 |
20-100 |
5 |
0.3 |
60-300 |
6 |
1 |
200-1000 |
7 |
3 |
600-3000 |
8 |
10 |
2000-10000 |
9 |
30 |
6000-30000 |
10 |
100 |
20000-100000 |
11 |
300 |
60000-300000 |
|
|
MI.PP-1030 Bomb Calorimeter (Digital)
For determination of heat combustion of organic
matter and calorific value and sulphur content of coal, solid and liquid
fuels. The bomb has a capacity of 300ml approximately a provided with a high
pressure Schroder valve. Tested as per the recruitment of institute of
petroleum (Supplied with, bomb calorimeter vessel with bomb support, water
jacket, combined lid for calorimeter vessel and water jacket, stirrer,
connecting leads, connecting tube to connect to bomb and pressure gauge.
Connecting tube with fine adjustment valve to connect pressure gauge and
oxygen cylinder pressure gauge. Connecting tube spanner for oxygen tube
connection, ignition wire (2 meter) Nicrome, cotton reel, stand for unit,
pallets press, digital beckman, thermometer benzoic acid, 'O' ring small,
'O' ring for stirrer. Valve for bomb and valve key.
Meets:- IP 12/63T
Supplied without oxygen cylinder (optional)